Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1283608.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/11/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date: 07/03/2018
Final Order: 05/28/2019
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/28/2019 | $0.00 | Serious | ||
Penalty | C: Contested | 07/18/2018 | $0.00 | Serious | ||
Penalty | Z: Issued | 06/11/2018 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about December 16, 2017, the employer did not ensure employees implemented energy control procedures during the clearing of jams (service and maintenance activity) on the Inedible Food Plant short auger, by turning off and/or shutting down [per the 1910.147(d)(2) requirements], isolating all energy sources [(d)(3)], affixing a lockout device to each energy isolating device [(d)(4)(i)], and verifying the equipment energy was isolated and de-energized prior to starting work [(d)(6)