Violation Detail
Standard Cited: 19100179 L03 III Overhead and gantry cranes.
Inspection Nr: 1255445.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $0.00
Issuance Date: 02/06/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 02/16/2018
Gravity: 10
Report ID: 0213400
Contest Date:
Final Order: 03/13/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/13/2018 | $0.00 | 02/16/2018 | Serious | |
Penalty | Z: Issued | 02/06/2018 | $12,934.00 | 02/16/2018 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.179(l)(3)(iii): Repairs or replacements were not provided promptly as needed for safe operation of crane(s): a) 1 Crossman Road North, Sayreville, NJ: The employer did not ensure that the worn and deformed hook on the Set up Shop P&H 10 ton crane had been removed from service until repaired or replaced. This hazard was observed on 8/14/17.