Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1254772.015
Citation: 01003B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/04/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/28/2017
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 12/22/2017
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/22/2017 | $0.00 | 12/28/2017 | Serious | |
Penalty | Z: Issued | 12/04/2017 | $0.00 | 12/28/2017 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6). a) Fresenius USA Manufacturing, Inc., on or about August 8, 2017, the employer did not ensure that the established procedures for the application of energy control for the Federal All Stainless Bottle Filler, serial number 2462, on the bottling line covered the actions listed in and was done in the sequence as required by 29 CFR 1910.147(d)(1)-(6), exposing employees to electrical and mechanical hazards.