Violation Detail
Standard Cited: 19260502 D11 Fall protection systems criteria and practices.
Inspection Nr: 1249360.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/25/2017
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 10
Report ID: 0215800
Contest Date:
Final Order: 10/02/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 08/25/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded: a) South side of roof, east end, on or about 7-20-17: Four employees were working at the edge of a barrel roof while connected to ropes that were passing over/in contact with sheet metal roof brackets, and not protected from abrasion, exposing the employees to a fall hazard of 26 feet 3 inches to the ground below. b) South side of roof, west end, on or about 7-20-17: Four employees were working at the edge of a barrel roof while connected to ropes that were passing over/in contact with sheet metal roof brackets, and not protected from abrasion, exposing the employees to a fall hazard of 10 feet 8 inches to a lower roof.