Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1222762.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,873.00
Current Penalty: $0.00
Issuance Date: 07/28/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/03/2017
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 08/21/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/21/2017 | $0.00 | 08/03/2017 | Serious | |
| Penalty | Z: Issued | 07/28/2017 | $8,873.00 | 08/03/2017 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) The employer did not ensure that hazardous energy control procedures were utilized (conveyor shut down and locked out) during servicing and maintenance operations. On or about April 6, 2017, an employee was cleaning the top of the out feed conveyor and was caught in the conveyor..