Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1220246.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/15/2017
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 04/01/2018
Gravity: 5
Report ID: 0521400
Contest Date:
Final Order: 10/03/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | $0.00 | 04/01/2018 | Serious | ||
| Penalty | P: Petition to Mod Abatement | $0.00 | 02/01/2018 | Serious | ||
| Penalty | I: Informal Settlement | 10/03/2017 | $0.00 | 12/01/2017 | Serious | |
| Penalty | Z: Issued | 09/15/2017 | $0.00 | 11/06/2017 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(c)(4)(i): The employer did not ensure procedures were utilized for the control of potentially hazardous energy when employees were engaged in machine set-up (servicing) activities: Bolt Header Department- On or about June 1, 2017 employees were exposed to amputations from unexpected start-up while performing set-up (servicing) at the point of operation and were permitted to rely on machine controls and switches rather than utilizing hazardous energy isolation methods. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).