Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1213029.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/21/2017
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 08/18/2017
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 08/10/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/10/2017 | $0.00 | 08/18/2017 | Serious | |
| Penalty | Z: Issued | 07/21/2017 | $0.00 | 08/18/2017 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) Production area; Power transmission belts were not guarded on equipment including, but not limited to the guillotine shear table.
Translate