Violation Detail
Standard Cited: 19100134 E01 Respiratory Protection.
Inspection Nr: 1145409.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/04/2016
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 12/09/2016
Gravity: 5
Report ID: 0213400
Contest Date:
Final Order: 12/02/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/02/2016 | $0.00 | 12/09/2016 | Serious | |
Penalty | Z: Issued | 11/04/2016 | $0.00 | 12/09/2016 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or was required to use the respirator in the workplace: Santec Inc./Linden, NJ- Production Area/Mixing Area: The Employer did not provide medical evaluations for employees who were required to wear respirators in the workplace. Employees were required to wear respiratory protection such as but not limited to: a) Sperian, half face air-purifying respirator (APR) b) 3M, N95 filtering face piece respirator Condition observed on or about May 5, 2016.