Violation Detail
Standard Cited: 19100253 B04 III Oxygen-fuel gas welding and cutting.
Inspection Nr: 1135880.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/29/2016
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 10/19/2016
Gravity: 5
Report ID: 0213400
Contest Date:
Final Order: 10/11/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/11/2016 | $0.00 | 10/19/2016 | Serious | |
Penalty | Z: Issued | 09/29/2016 | $0.00 | 10/19/2016 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) Mavis Tire Supply Corp. dba Mavis Discount Tires/Westfield, NJ- Back Room Area: Employer did not ensure that Oxygen cylinder was separated from a fuel gas cylinder. Oxygen and Acetylene cylinders were stored next to each other. Condition observed on or about March 30, 2016.