Standard Cited: 19100217 C03 III F Mechanical power presses.
Inspection Nr: 1128049.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/29/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/04/2016
Gravity: 10
Report ID: 0522500
Contest Date: 07/21/2016
Final Order: 03/16/2018
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/16/2018 | $0.00 | 08/04/2016 | Serious | |
Penalty | C: Contested | 07/28/2016 | $0.00 | 08/04/2016 | Serious | |
Penalty | Z: Issued | 06/29/2016 | $0.00 | 08/04/2016 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.217(c)(3)(iii)(f): Guards shall be used to protect all areas of entry to the point of operation not protected by the presence sensing device: a. On or about February 18, 2016, on the RY-3 press line, the employer did not ensure that light curtain presence sensing devices, of the adjacent idler station, were adjusted so that entry from the side of press 3 into the point of operation would be detected at all times and the press could not cycle. The light curtains did not protect employees from the point of operation in that the light curtains were not installed correctly and could be reset automatically by initiating the presses while employees were in the danger zone.