Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1118903.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/24/2016
Nr Instances: 5
Nr Exposed: 20
Abatement Date: 07/09/2016
Gravity: 10
Report ID: 0625400
Contest Date:
Final Order: 09/29/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/29/2016 | $0.00 | 07/09/2016 | Serious | |
Penalty | Z: Issued | 06/24/2016 | $0.00 | 07/09/2016 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: On or about January 11, 2016, the employer failed to ensure the employees were trained and they had the knowledge and skills for the safe application, usage and removal of energy control devices when maintaining, cleaning, unjamming equipment such as, but not limited to: a) Paint department, UV Sander (Stiles). b) Machinery department, Sigma 90 plus panel saw. c) Machinery department, Holzma panel saw. d) Machinery department, Homag H bander saw. e) Machinery department, Weeke ABD 100 CNC machine. f) Glue department, glue roller when cleaning it.