Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1076213.015
Citation: 01003B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/07/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/27/2015
Gravity: 5
Report ID: 0522000
Contest Date: 10/27/2015
Final Order: 05/25/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/25/2016 | $0.00 | 10/27/2015 | Serious | |
Penalty | C: Contested | 10/27/2015 | $0.00 | 10/27/2015 | Serious | |
Penalty | Z: Issued | 10/07/2015 | $0.00 | 10/27/2015 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.147(d): The established procedures for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in the sequence as required by 29 C.F.R. 1910.147(d)(1)-(6): In the production areas of the Treif #1 and #2 machines, the machine operators were exposed to an amputation hazard while unjamming the swirl roll product by opening the plexiglass cover on an inadequate machine safeguarding system.