Violation Detail
Standard Cited: 19100107 E02 Spray finishing using flammable and combustible materials.
Inspection Nr: 992612.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,500.00
Current Penalty: $3,825.00
Issuance Date: 02/12/2015
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0636900
Contest Date: 03/16/2015
Final Order: 12/07/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 12/07/2015 | $3,825.00 | Serious | ||
| Penalty | C: Contested | 06/01/2015 | $4,500.00 | Serious | ||
| Penalty | Z: Issued | 02/12/2015 | $4,500.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift. On or about August 28, 2014, in the coating department, class 3 liquids such as, but not limited to black flat low friction coating was stored inside the spray booth and exceeded the daily usage limit. There were approximately 5-10 one gallon containers of paint and other chemicals located in the paint booth exposing employees to fire and explosion hazards.