Standard Cited: 19100179 J03 X Overhead and gantry cranes.
Inspection Nr: 909213.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,500.00
Current Penalty: $3,500.00
Issuance Date: 12/09/2013
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 12/24/2013
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 01/07/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 12/09/2013 | $3,500.00 | 12/24/2013 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.179(j)(3)(x): Electrical apparatus were not inspected periodically for signs of pitting or any deterioration of controller contactors, limit switches and pushbutton stations: a) On or about May 30, 2013, in the company's air set 4 - cel 600 room, the pendant control of the Dayton 1 ton crane with serial number 11C637NS was not inspected, exposing emloyees to struck-by hazards. b) On or about May 30, 2013, in the company's no bake room, the pendant control of the P&H 3 ton crane was not inspected, exposing employees to struck-by hazards.