Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 904530.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 08/27/2013 2
Initial Penalty: $5,390.00
Current Penalty: $4,042.50
Issuance Date: 08/15/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0418200
Contest Date: 01/03/2014
Final Order: 06/16/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/16/2014 | $4,042.50 | 08/27/2013 | Serious | |
Penalty | C: Contested | 01/07/2014 | $5,390.00 | 08/27/2013 | Serious | |
Penalty | Z: Issued | 08/15/2013 | $5,390.00 | 08/27/2013 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains that were seven (7) or less feet from the floor or platform were not enclosed: a) Planer Mill: The chains on a portion of the conveyor motor were not guarded, exposing employees to ingoing nip points and rotating parts.