Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 899219.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,250.00
Current Penalty: $2,975.00
Issuance Date: 06/27/2013
Nr Instances: 4
Nr Exposed: 11
Abatement Date:
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 07/23/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/23/2013 | $2,975.00 | Serious | ||
| Penalty | Z: Issued | 06/27/2013 | $4,250.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Pulleys located on the Crack Corn Cleaner were not guarded to prevent employees from contacting them. (b) Pulleys located on the garage door opener in the grain loading bay of the pellet extrusion facility were not completely guarded. (c) Pulleys located on the top of elevator leg 68 were not guarded to prevent employees from contacting them. (d) Pulleys located on top of an elevator leg in the cleaning mill area of the Pet and Wild Bird facility were not guarded. NO ABATEMENT CERTIFICATION OR DOCUMENTATION REQUIRED