Violation Detail
Standard Cited: 19260451 B01 General requirements.
Inspection Nr: 874523.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $2,800.00
Current Penalty: $2,800.00
Issuance Date: 04/01/2013
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/03/2013
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 04/24/2013
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 04/01/2013 | $2,800.00 | 04/03/2013 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about February 6, 2013, at the worksite located at 86 Tournay Circle, Little Rock, Arkansas, supported scaffold at the north end of the home being built, the 1st level platform and 2nd level cantilevered platform that employees worked from to perform masonry activities were not fully decked. This condition exposed employees to falls from elevation.