Violation Detail
Standard Cited: 19100110 E04 III Storage and handling of liquefied petroleum gases.
Inspection Nr: 282158.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,000.00
Current Penalty: $2,550.00
Issuance Date: 09/20/2012
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 09/27/2012
Gravity: 1
Report ID: 0214700
Contest Date: 10/11/2012
Final Order: 03/15/2013
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/15/2013 | $2,550.00 | 09/27/2012 | Serious | |
Penalty | C: Contested | 10/19/2012 | $3,000.00 | 09/27/2012 | Serious | |
Penalty | Z: Issued | 09/20/2012 | $3,000.00 | 09/27/2012 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating: a) Workplace, Loading Dock - Nissan 50 Forklift, #5 (orange) had a broken off LPG tank location pin. The stub of the pin left was too short to reach the tank to keep it from rotating; on or about 03/27/12 b) Workplace, Loading Dock - Clark CMP 30 Forklift, #1 (green) Serial CP23OL-0154-6872KF had the LPG tank was mounted improperly without mounting the tank on the location pin; on or about 03/27/12 c) Workplace, Loading Dock - Poosan Daewoo G25E-3 Forklift #4 (yellow) Serial KP-00509 the LPG tank was mounted improperly without mounting the tank on the location pin. The location pin on this machine was repaired with a pin that was too large in diameter to fit the standard hole in LPG tanks; on or about 03/27/12 Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.