Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1787526.015
Citation: 01003A
Citation Type: Serious
Abatement Status:
Initial Penalty: $16,550.00
Current Penalty: $16,550.00
Issuance Date: 01/30/2025
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 02/19/2025
Gravity: 10
Report ID: 0522500
Contest Date: 02/26/2025
Final Order:
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 04/08/2025 | $16,550.00 | 02/19/2025 | Serious | |
Penalty | Z: Issued | 01/30/2025 | $16,550.00 | 02/19/2025 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. a) Located at 150 Fourth Avenue, Mount Sterling, OH 43143: On or about November 13, 2024, the employer did not ensure employees utilized the energy control procedure to perform servicing and maintenance activities, including setting up the extruder. Employees did not perform lockout/tagout and were exposed to pinch point hazards as a result. b) Located at 150 Fourth Avenue, Mount Sterling, OH 43143: On or about November 12, 2024, the employer did not ensure employees utilize the energy control procedure to perform servicing and maintenance activities to include removing vent needles. Employees did not perform lockout/tagout and were exposed to pinch point hazards as a result.