Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1771676.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,610.00
Current Penalty: $3,227.00
Issuance Date: 12/05/2024
Nr Instances: 2
Nr Exposed: 11
Abatement Date:
Gravity: 5
Report ID: 0626600
Contest Date: 02/10/2025
Final Order: 03/26/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/26/2025 | $3,227.00 | Serious | ||
Penalty | C: Contested | 03/10/2025 | $4,610.00 | Serious | ||
Penalty | Z: Issued | 12/05/2024 | $4,610.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.212(a)(5):Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: 1. On or about August 27, 2024, at the loading dock employees were using a large box fan that had gaps in the front guard exposing the fan blades. 2. On or about August 27, 2024, at the radial arm saw work area an employee was utilizing a large box fan that had gaps in the front guard exposing fan blades.