Violation Detail
Standard Cited: 19260652 G01 II Requirements for protective systems.
Inspection Nr: 1750946.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $7,098.00
Current Penalty: $7,098.00
Issuance Date: 09/27/2024
Nr Instances: 2
Nr Exposed: 1
Abatement Date: 10/09/2024
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 10/23/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/27/2024 | $7,098.00 | 10/09/2024 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1926.652(g)(1)(ii): Shields shall be installed in a manner to restrict lateral or other hazardous movement of the shield in the event of the application of sudden lateral loads: a) On or about May 28, 2024, at a worksite located along Mid Valley Road, De Pere, Wisconsin; an employee working within a trench with two trench boxes stacked on one another was not protected from the application of sudden lateral loads, as the area on the sides of the trench shields was not back filled to prevent movement. b) On or about May 29, 2024, at a worksite located along Mid Valley Road, De Pere, Wisconsin; an employee working within a trench with one trench box and multiple steel plates driven alongside it was not protected from the application of sudden lateral loads, as the area on the sides of the trench shield and plates were not backfilled to prevent movement.