Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1730185.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,296.00
Current Penalty: $4,000.00
Issuance Date: 07/02/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/29/2024
Gravity: 5
Report ID: 0524200
Contest Date:
Final Order: 08/05/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/05/2024 | $4,000.00 | 07/29/2024 | Serious | |
Penalty | Z: Issued | 07/02/2024 | $8,296.00 | 07/29/2024 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1): Pulleys, with parts of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section: a) Production Area - On February 21, 2024, the employer did not ensure that the Dipping Machines #4, and #5, had the belt and pulley completely guarded to prevent contact with the moving parts. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).