Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1729247.015
Citation: 01003A
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $9,795.00
Current Penalty: $6,856.50
Issuance Date: 05/03/2024
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 05/28/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/28/2024 | $6,856.50 | Other | ||
Penalty | Z: Issued | 05/03/2024 | $9,795.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed. (a) On or about February 21, 2024, located at 150 Holy Hill Road, Twin Lakes, WI 53181, the employer did not evaluate the company's hazardous energy control program annually to ensure machine specific energy control procedures were current, and that authorized employees were correctly implementing energy control procedures when performing services and maintenance on the MAAC#1 and MAAC #10 Thermoform Equipment.