Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1654794.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $15,625.00
Current Penalty: $12,500.00
Issuance Date: 08/30/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 09/29/2023
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/29/2023 | $12,500.00 | Serious | ||
Penalty | Z: Issued | 08/30/2023 | $15,625.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a) At the amusement park, where the electric and kinetic energy sources were not de-energized after an employee repositioned the 22M Giant Loop roller coaster during an inspection.