Standard Cited: 19100169 A02 I Air receivers.
Inspection Nr: 1571874.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,230.00
Current Penalty: $3,922.50
Issuance Date: 02/18/2022
Nr Instances: 2
Nr Exposed: 4
Abatement Date: 07/07/2023
Gravity: 1
Report ID: 0112000
Contest Date:
Final Order: 03/25/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 05/25/2022 | $3,922.50 | 07/07/2023 | Serious | |
Penalty | I: Informal Settlement | 03/25/2022 | $3,922.50 | 07/07/2023 | Serious | |
Penalty | Z: Issued | 02/18/2022 | $5,230.00 | 04/07/2022 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.169(a)(2)(i): Air receivers were not constructed in accordance with the 1968 edition of the A.S.M.E. Boiler and Pressure Vessel Code, Section VIII, which is incorporated by reference as specified in 1910.6: Kummer Cell: On, or about, January 10, 2022, two shop-fabricated air receiver tanks were used to supply compressed air to the bench mounted pneumatic presses. The end fitting on each tank appeared to be standard malleable fittings with a working pressure of 150 p.s.i.g. The pressure in each receiver tank was 160 p.s.i.g. Abatement Note: Guidelines for piping system closures are included in recognized and generally accepted industry guidelines for power piping systems such as American National Standard (ANSI) B31.1 Power Piping.