Violation Detail
Standard Cited: 19100179 G02 I Overhead and gantry cranes.
Inspection Nr: 1508934.015
Citation: 01003A
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $7,802.00
Current Penalty: $4,291.10
Issuance Date: 01/28/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0729700
Contest Date:
Final Order: 02/19/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/19/2021 | $4,291.10 | Other | ||
Penalty | Z: Issued | 01/28/2021 | $7,802.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.179(g)(2)(i):Electrical equipment was not so located or enclosed that live parts would not be exposed to accidental contact under normal operating conditions: At the Roll Packing Area, employees engaged in material handling activities were exposed to electrical hazards in that the power cord to the Dayton Hoist had exposed wires at the connector. 29 CFR 1903.19(c)(2) abatement of the above violation was verified at time of inspection, no certification is required.