Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1455831.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $10,000.00
Issuance Date: 04/17/2020
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 12/09/2021
Gravity: 10
Report ID: 0213100
Contest Date: 05/08/2020
Final Order: 12/09/2021
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/09/2021 | $10,000.00 | 12/09/2021 | Serious | |
Penalty | C: Contested | 07/31/2020 | $13,494.00 | 04/23/2020 | Serious | |
Penalty | Z: Issued | 04/17/2020 | $13,494.00 | 04/23/2020 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Line 1 Can Conveying Wet Elevator Area in the Front End- On or about January 7, 2020, procedures were not utilized for the Line 1 Can Conveying Wet Elevator to clear a jam. b) Line 1 South Trench Conveyor in the Front End - On or about January 7, 2020, procedures were not utilized for the Line 1 South Trench Conveyor when an employee needed to access the Line 1 Trench to replace a belt on the Line 1 North Trench Conveyor that is located approximately 12 inches directly next to the Line 1 South Trench Conveyor.