Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1449388.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,241.00
Current Penalty: $2,250.00
Issuance Date: 02/18/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0521700
Contest Date:
Final Order: 03/12/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/12/2020 | $2,250.00 | Serious | ||
Penalty | Z: Issued | 02/18/2020 | $4,241.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a. On or about December 5, 2019, at the above addressed jobsite, a portable ladder used to access the roof did not extend at least three (3') feet above the upper landing surface, was not secured at its top to a rigid support, and a grasping device was not provided, thereby exposing employees to the hazards associated with falls.