Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1415647.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 09/17/2019 2
Initial Penalty: $11,934.00
Current Penalty: $8,353.80
Issuance Date: 07/31/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 08/19/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/19/2019 | $8,353.80 | 09/17/2019 | Serious | |
Penalty | Z: Issued | 07/31/2019 | $11,934.00 | 09/17/2019 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(d)(2): An orderly shutdown of the machine or equipment was not utilized to avoid any additional or increased hazards to employees as a result of equipment stoppage: At 1120 Mason Circle S., the orderly shutdown of the Normac #1 Grinding Machine, m/n BS-35, was not performed in that the grinding wheel was still spinning (kenetic energy) when the authorized employee opened the door (guard) and placed his left hand into the danger zone. This action resulting in an amputation on or about 07/15/19. This violation was noted on 07/23/19.