Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1403205.015
Citation: 01003A
Citation Type: Serious
Abatement Status:
Initial Penalty: $9,282.00
Current Penalty: $0.00
Issuance Date: 11/01/2019
Nr Instances: 1
Nr Exposed: 45
Abatement Date: 12/20/2019
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 11/19/2019
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/19/2019 | $0.00 | 12/20/2019 | Serious | |
Penalty | Z: Issued | 11/01/2019 | $9,282.00 | 12/20/2019 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about August 5, 2019, employee(s) were exposed to machine hazards associated with moving parts and in-going nip points during servicing and cleaning of the point of operation on the Klingelnberg #123 CNC Model No. JR/C (SN 1664) and the Wenzel Prazision #124 CNC Model No. D-8771 (SN 27207/2) located in the production department. The employer failed to ensure that energy control procedures were utilized when servicing and cleaning at the point of operation. The electrical components of the equipment were not disconnected and locked-out, nor were the pneumatic energy sources dissipated, isolated, or locked-out.