Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1397687.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,630.00
Current Penalty: $3,978.00
Issuance Date: 06/14/2019
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 07/03/2019
Gravity: 5
Report ID: 0626600
Contest Date:
Final Order: 07/19/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/19/2019 | $3,978.00 | 07/03/2019 | Serious | |
Penalty | Z: Issued | 06/14/2019 | $6,630.00 | 07/03/2019 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219 (m) and (o). On or about May 1, 2019: a. In the Winder Shop, on the west wall of the facility, where employees were exposed to a caught-by hazard while working adjacent to Coil Winder, Potter and Rayfield, no ID number without a guarded pulley. b. In the Winder Shop, on the west wall of the facility, where employees were exposed to a caught-by hazard while working adjacent to Coil Winder, Potter and Rayfield, Global Asset #104, without a guarded pulley.