Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1385506.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $10,419.00
Current Penalty: $10,419.00
Issuance Date: 06/18/2019
Nr Instances: 1
Nr Exposed: 12
Related Event Code (REC):
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 07/16/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/16/2019 | $10,419.00 | Serious | ||
Penalty | Z: Issued | 06/18/2019 | $10,419.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: At the time of the inspection, the drive motor shaft for the rotary valve below the waste hopper in the Pugger room extended more than 1/2 the diameter of the shaft with an exposed keyway.