Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1366578.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,366.00
Current Penalty: $11,366.00
Issuance Date: 05/14/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/17/2019
Gravity: 5
Report ID: 0728500
Contest Date:
Final Order: 06/06/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/06/2019 | $11,366.00 | 06/17/2019 | Serious | |
| Penalty | Z: Issued | 05/14/2019 | $11,366.00 | 06/17/2019 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: The employer is failing to protect employees from stored or residual energy sources such as electrical and mechanical hazards while performing servicing or maintenance to the Nutters. The employer did not provide machine specific lockout/tagout procedures to be used by employees to prevent the unexpected energization, start up or release of stored energy for the Nutters.
Translate