Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1322941.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,174.00
Current Penalty: $2,592.00
Issuance Date: 07/05/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 07/31/2018
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 07/24/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/24/2018 | $2,592.00 | 07/31/2018 | Serious | |
| Penalty | Z: Issued | 07/05/2018 | $5,174.00 | 07/31/2018 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): (a) Pelletizer: On or about June 13, 2018 and at times prior, employees operate the pelletizer while exposed to a rotating belt driven pulley. Note: Abatement certification and documentation is required for this item.