Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1308450.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,054.00
Current Penalty: $5,432.00
Issuance Date: 08/28/2018
Nr Instances: 2
Nr Exposed: 1
Abatement Date: 10/18/2018
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 09/20/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/20/2018 | $5,432.00 | 10/18/2018 | Serious | |
| Penalty | Z: Issued | 08/28/2018 | $9,054.00 | 10/18/2018 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): 220 Kenneth Welch Drive, Lakeville, Ma. The electrical disconnect box for the condenser belt was in close proximity to the rotating belt and exposed employees to the rotating belt. A worker was injured at a belt and pulley pinchpoint.
Translate