Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1285525.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,467.00
Current Penalty: $2,500.00
Issuance Date: 05/24/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/20/2018
Gravity: 5
Report ID: 0213900
Contest Date: 09/06/2018
Final Order: 01/30/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 01/30/2019 | $2,500.00 | 06/20/2018 | Serious | |
Penalty | C: Contested | 09/10/2018 | $6,467.00 | 06/20/2018 | Serious | |
Penalty | Z: Issued | 05/24/2018 | $6,467.00 | 06/20/2018 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) JVK Operations, Ltd. - Dryer area: The right side of the Lavatec dryer #1, Type T56G/u, S/N 7560319 has a guard missing to cover a belt and pulley, observed on or about 12/19/2017.