Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1258814.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,339.00
Current Penalty: $3,802.00
Issuance Date: 10/30/2017
Nr Instances: 1
Nr Exposed: 14
Abatement Date:
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 11/16/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/16/2017 | $3,802.00 | Serious | ||
Penalty | Z: Issued | 10/30/2017 | $6,339.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about August 25, 2017, the employer did not have written specific lockout/tagout procedures for machinery such as but not limited to the saturation room machinery and the tube filler machine.