Violation Detail
Standard Cited: 19100107 C02 Spray finishing using flammable and combustible materials.
Inspection Nr: 1254109.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,338.00
Current Penalty: $3,169.00
Issuance Date: 12/06/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/15/2017
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 12/22/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/22/2017 | $3,169.00 | 12/15/2017 | Serious | |
Penalty | Z: Issued | 12/06/2017 | $6,338.00 | 12/15/2017 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.107(c)(2): There was open flame or spark producing equipment in the spraying area or within 20 feet thereof, and not separated by a partition. a. CDC Fab Co. located in Maumee, Ohio: On or about August 10, 2017, the employer did not ensure spark producing equipment, such as but not limited to, the wall fan was prohibited when within 20 feet of the spraying area containing combustible adhesive residue.