Violation Detail
Standard Cited: 19100253 B02 II Oxygen-fuel gas welding and cutting.
Inspection Nr: 1238964.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $1,847.00
Current Penalty: $1,847.00
Issuance Date: 06/20/2017
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 07/24/2017
Gravity: 1
Report ID: 0729300
Contest Date:
Final Order: 07/20/2017
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 06/20/2017 | $1,847.00 | 07/24/2017 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior: a. One unsecured oxygen cylinder was setting on the floor next to the cutting torch cart, and two were setting unsecured next to the north overhead door. b. Unsecured oxygen cylinders were periodically stored with combustible liquid/gas cylinders, including acetylene cylinder(s) and propane tanks, next to the east overhead door. c. One unsecured acetylene cylinder was setting on the floor by the east overhead door. Abatement documentation is required for this violation.