Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1234196.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,675.00
Current Penalty: $7,605.00
Issuance Date: 11/08/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/20/2017
Gravity: 10
Report ID: 0524500
Contest Date:
Final Order: 12/04/2017
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/04/2017 | $7,605.00 | 11/20/2017 | Serious | |
Penalty | Z: Issued | 11/08/2017 | $12,675.00 | 11/20/2017 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about May 17, 2017, an employee was exposed to the unguarded ingoing nip point on the friction roller pulley on the Modern Cut-Off Machine in the Machine Department.