Violation Detail
Standard Cited: 19100119 E05 Process safety management of highly hazardous chemicals.
Inspection Nr: 1157891.015
Citation: 01003A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $8,729.00
Current Penalty: $4,500.00
Issuance Date: 11/15/2016
Nr Instances: 1
Nr Exposed: 48
Abatement Date: 01/15/2017
Gravity:
Report ID: 0627700
Contest Date:
Final Order: 12/05/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/05/2016 | $4,500.00 | 01/15/2017 | Other | |
| Penalty | Z: Issued | 11/15/2016 | $8,729.00 | 12/30/2016 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.119(e)(5): The employer did not establish a system to promptly address the team's findings and recommendations. Instance a) This violation was most recently observed on or about June 21, 2016 and times prior thereto and times thereafter, in the Refrigeration Process at American Cold Storage (ACS) located in Tulsa, Oklahoma when the employer did not address the 2009 PHA team's findings and recommendations including but not limited to implementing corrosion inspections when insulation was removed, missing and/or damaged on piping system. Instance b) This violation was most recently observed on or about June 21, 2016 and times prior thereto and times thereafter, in the Refrigeration Process at American Cold Storage (ACS) located in Tulsa, Oklahoma when the employer did not address the 2009 PHA team's findings and recommendations including but not limited to conducting emergency mock drills.