Violation Detail
Standard Cited: 19100146 C01 Permit-required confined spaces
Inspection Nr: 1123539.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,000.00
Current Penalty: $6,506.00
Issuance Date: 07/22/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0418200
Contest Date:
Final Order: 08/10/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/10/2016 | $6,506.00 | Serious | ||
Penalty | Z: Issued | 07/22/2016 | $7,000.00 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: (a) Plant, Basement beneath the Hammer Mill: Employees were exposed to caught-in hazards because areas such as the auger beneath the hammer mill was not evaluated and identified as permit required confined spaces.