Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1109683.015
Citation: 01003A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $4,000.00
Current Penalty: $2,800.00
Issuance Date: 02/04/2016
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 02/17/2016
Gravity:
Report ID: 0418400
Contest Date: 03/03/2016
Final Order: 08/29/2016
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 08/29/2016 | $2,800.00 | 02/17/2016 | Other | |
| Penalty | C: Contested | 03/10/2016 | $4,000.00 | 02/17/2016 | Serious | |
| Penalty | Z: Issued | 02/04/2016 | $4,000.00 | 02/17/2016 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Blanching Area, Building PB1, behind the blanching machine conveyor, on or about 11-30-2015, employer failed to provide appropriate enclosure to belts and pulley to protect employees working with and around the blanching machinery, there were gaps in the guarding or enclosures of the belts and pulleys that leave them partially exposed to accidental contact resulting in lacerations.