Violation Detail
Standard Cited: 19100134 C01 Respiratory Protection.
Inspection Nr: 1082893.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,800.00
Current Penalty: $1,960.00
Issuance Date: 10/07/2015
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 11/03/2015
Gravity: 5
Report ID: 0418400
Contest Date:
Final Order: 10/28/2015
Related Event Code (REC):
Emphasis:
Substance: P125
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/28/2015 | $1,960.00 | 11/03/2015 | Serious | |
Penalty | Z: Issued | 10/07/2015 | $2,800.00 | 11/03/2015 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103): (a) Pooler construction site, on or about and at times preceding to August 4, 2015, the employer had not developed a written respiratory protection program for required use of respirators including Bullard fresh air hood, used for foaming application, and 3M half mask used for R17 and R13 insulation installation.