Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1019776.015
Citation: 01003A
Citation Type: Serious
Abatement Date: 02/27/2015 7
Initial Penalty: $3,080.00
Current Penalty: $3,080.00
Issuance Date: 02/17/2015
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 04/16/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 02/17/2015 | $3,080.00 | 02/27/2015 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a. Located at the Trotters Gate Apartments Clubhouse, employees were using a 20 foot fiberglass extension ladder that extended approximately 1 foot above the parapet wall to access the roof of the building. Employees were exposed to an approximately 16 foot fall hazard while accessing the roof.