Violation Detail
Standard Cited: 19100023 E01 Ladders.
Inspection Nr: 998534.015
Citation: 01003
Citation Type: Serious
Abatement Date: 03/26/2015 2
Initial Penalty: $5,000.00
Current Penalty: $2,975.00
Issuance Date: 02/06/2015
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 02/24/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/24/2015 | $2,975.00 | 03/26/2015 | Serious | |
Penalty | Z: Issued | 02/06/2015 | $5,000.00 | 03/26/2015 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.23(e)(1): A standard railing did not consist of top rail, intermediate rail, and posts, and did not have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level: a/ Inside of the Production Area, the railing along the open edge of a platform over the Age Oven consisted of a top rail only. The vertical height of this top rail was approximately 35 inches above the platform. The height of this platform was approximately 11 feet above the concrete floor.