Violation Detail
Standard Cited: 19261053 B16 Ladders.
Inspection Nr: 998219.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,000.00
Current Penalty: $2,000.00
Issuance Date: 12/04/2014
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0418200
Contest Date:
Final Order: 12/08/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 12/04/2014 | $2,000.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately. a) West side wall of the house at 5257 Autumn Run Dr. SW, Powder Springs, GA: Employees were exposed to falls of approximately 17 feet while using a damaged aluminum extension ladder to access the roof of a single family home during shingle and felt installation.