Violation Detail
Standard Cited: 19100219 C02 Mechanical power-transmission apparatus.
Inspection Nr: 993386.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $3,400.00
Current Penalty: $2,100.00
Issuance Date: 03/02/2015
Nr Instances: 2
Nr Exposed: 29
Abatement Date:
Gravity: 5
Report ID: 0213400
Contest Date: 03/24/2015
Final Order: 07/13/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 07/13/2015 | $2,100.00 | Serious | ||
Penalty | C: Contested | 03/25/2015 | $3,400.00 | Serious | ||
Penalty | Z: Issued | 03/02/2015 | $3,400.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(c)(2): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, were not protected by a stationary casing enclosing shafting completely: 125 Factory Ln, Middlesex, NJ site - Process area: Employer did not provide stationary casing on horizontal shafts. a) Still #2 - Moving parts of the horizontal shafting of the motors which control the agitators inside of Stills #1 not adequately guarded. b) Still #1 - Rotating horizontal shaft on the ground level motor was not adequately guarded as the metal guard was damaged. Condition noted on or about 09/04/2014.