Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 985545.015
Citation: 01003
Citation Type: Serious
Abatement Status: Not Completed - Employer Out of Business
Initial Penalty: $6,300.00
Current Penalty: $6,300.00
Issuance Date: 01/14/2015
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 02/10/2015
Gravity: 10
Report ID: 0521400
Contest Date: 02/04/2015
Final Order: 06/22/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/22/2016 | $6,300.00 | 02/10/2015 | Serious | |
Penalty | C: Contested | 02/04/2015 | $6,300.00 | 02/10/2015 | Serious | |
Penalty | Z: Issued | 01/14/2015 | $6,300.00 | 02/10/2015 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: The employer did not ensure that energy control procedures were inspected at least annually to ensure that procedures were in were compliant with 1910.147 while performing servicing and maintenance. Employees were exposed to unexpected start-up of machinery while utilizing inadequate procedures that were not inspected at least annually. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).