Violation Detail
Standard Cited: 19260416 A01 General requirements.
Inspection Nr: 979641.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,900.00
Current Penalty: $3,430.00
Issuance Date: 11/28/2014
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 12/15/2014
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/15/2014 | $3,430.00 | Serious | ||
| Penalty | Z: Issued | 11/28/2014 | $4,900.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: On or about June 4, 2014, at the above addressed site, employees applying a plastic film to existing windows from the basket of an aerial lift were exposed to severe electrical shock injuries, burns and or death while working in proximity of overhead power lines energized with 7,620 volts.
Translate